  • Foundation bolt/cage to be fully welded construction in accordance with AS1554.1 weld symbols comply with AS1103.3
  • Hot dip galvanised after fabrication
  • Concrete to have a minimum characteristic strength of 32MPa or 40MPa where an exposure classification of moderate is determined
  • Minimum clear concrete cover to be 65mm
  • All concrete shall be placed and vibrated to optimum compaction
  • Pile casings to be used for constructions purposes where required
  • Engineering advice is to be sort where soils are assessed to be of exposure classification severe or greater
  • Soil classification to be determined by a geotechnical engineer

Product

Solar
Lighting
Designs

Solar Lighting Designs

©2024

Product Description.

SLD M20 FOUNDATION CAGE

This table is to be used as a guide only. All pile specifications should be confirmed with an appropriately qualified engineer prior to construction. M20 Foundation bolt/cage assembly on 233mm PCD. Based on average soil conditions. Certification by others.

Technical Data

SKU
SLDRBC001
Soil Type As defined in AS/NZS 4676: 2000 Appendix
Firm Damp Clays; Sandy Clays; Damp Sands Fb > 100KPa
Pile Diameter
450mm
Pile Length
1200mm
Cage Bolt Assembly
M20
Bolt Pattern
4 M20 on 233 PCD
Ultimate Base Moment
10.1 kNm
Ultimate Base Shear
2.5 KN